AL CANTOL 630

Description

Description

Standards

  • National
    AS/NZS 5000.1

Application

  • Industrial and commercial applications (predominantly)
  • Some domestic applications
  • For use in various situations to supply the main power from the point of supply (either single or three phase application) to buildings, equipment, eg, switch board to main control cabinet, main between floors and buildings, cable cabinet to motor, etc. Commonly used in Power Authority work.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Type of conductor
Circular compacted stranded
Insulation
XLPE
Outer sheath
PVC
Conductor flexibility
Class 2
Conductor shape
Circular
Sheath colour
Black
With Green/Yellow core
No
With smaller neutral conductor
No

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
630 mm²
Nominal overall diameter
39.4 mm
Gland Size (A2 or A2F)
50
Approximate weight
2.38 kg/m
Neutral conductor section (when smaller)
- mm²
Number of cores
1

Electrical characteristics

Electrical characteristics

Max. DC resistance of the conductor at 20°C (Ohm/km)
0.0469
Permissible short circuit current conductor 1s
- kA
Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Rigid

Usage characteristics

Usage characteristics

Max. conductor temperature in service
90 °C
U.V resistance
Yes

Resources

Resources

Current carrying capacities single phase (in Amps) - Single Conductor XLPE

Copper/ALuminium conductor - Circular compacted stranded - Insulation XLPE Max. Conductor Temperature 90⁰C
Conductor cross-section
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
630.0 1224 994 1045 849 0 0 1098 891 995 792 916 744 0
Air Spaced from Surface, Unenclosed
Air touching, unenclosed
Air enclosed
Buried direct
Buried in single-way duct
Buried in multi-way duct
Cable surrounded by thermal insulation, unenclosed

Current carrying capacities three phase (in Amps) - Single Conductor XLPE

Copper conductor - Circular compacted stranded - Insulation XLPE Aluminum conductor - Circular compacted stranded - Insulation XLPE Max. Conductor Temperature 90⁰C
Conductor cross-section
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
630.0 1111 906 1032 842 785 641 902 736 877 700 778 635 0
Air Spaced from Surface, Unenclosed
Air touching, unenclosed
Air enclosed
Buried direct
Buried in single-way duct
Buried in multi-way duct
Cable surrounded by thermal insulation, unenclosed

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close