 - Sign in
 
CU ENVIRO RHE-1-FLEX 3X 4+2.5E OG
CU ENVIRO RHE-1-FLEX 3X 4+2.5E OG
ENVIROLEX
Multicore flexible copper conductor, 0.6/1kV X-90 insulated, HFS-90-TP sheathed to AS/NZS 5000.1
Read more- Nexans ref. : FTHR06HF003OMRJ
 - Country ref. : 1202
 - EAN : 9319215467661
 
Description
Description
Standards
- 
                                            ProductAS/NZS 5000.1
 - 
                                            TestIEC 60332-1; IEC 60754-1
 
ENVIROLEX® flexible multicore cable is part of the Nexans Fire Safety Offer. As a Low Fire Hazard (LFH) range, ENVIROLEX® is PVC-free, made with flame retardant compound and reduces toxic smoke emissions in the event of fire, allowing time for safe evacuation.
- Class 5 flexible conductor
 - 0.6/1kV cables,
 - Flexible, X-90 insulated
 - HFS-90-TP sheathed to AS/NZS 5000.1 (Power)
 - 90°C continuous
 - Submersible to 500m
 - Used for fixed application
 
Characteristics
Characteristics
Construction characteristics
Construction characteristics
                                                                With Green/Yellow core
                                                            
                                                            
                                                                Yes 
                                                            
                                                        
                                                                Conductor material
                                                            
                                                            
                                                                Copper 
                                                            
                                                        
                                                                Type of conductor
                                                            
                                                            
                                                                Stranded copper 
                                                            
                                                        
                                                                Insulation
                                                            
                                                            
                                                                X-HF-90 
                                                            
                                                        
                                                                Outer sheath
                                                            
                                                            
                                                                HFS-90-TP 
                                                            
                                                        
                                                                Colour
                                                            
                                                            
                                                                Orange 
                                                            
                                                        
                                                                Conductor flexibility
                                                            
                                                            
                                                                Class 2 
                                                            
                                                        
                                                                Conductor shape
                                                            
                                                            
                                                                Circular 
                                                            
                                                        
                                                                Insulation colour
                                                            
                                                            
                                                                Red, White, Blue, Green/Yellow 
                                                            
                                                        
                                                                With smaller neutral conductor
                                                            
                                                            
                                                                No 
                                                            
                                                        Dimensional characteristics
Dimensional characteristics
                                                                Conductor cross-section
                                                            
                                                            
                                                                4 mm²
                                                            
                                                        
                                                                Number of cores
                                                            
                                                            
                                                                3 
                                                            
                                                        
                                                                Approximate weight
                                                            
                                                            
                                                                27.7 kg/100m
                                                            
                                                        
                                                                Maximum diameter of wires
                                                            
                                                            
                                                                0.31 mm
                                                            
                                                        
                                                                Neutral conductor section (when smaller)
                                                            
                                                            
                                                                - mm²
                                                            
                                                        
                                                                Nominal insulation thickness
                                                            
                                                            
                                                                0.7 mm
                                                            
                                                        
                                                                Nominal outer sheath thickness
                                                            
                                                            
                                                                1.8 mm
                                                            
                                                        
                                                                Nominal overall diameter
                                                            
                                                            
                                                                13.8 mm
                                                            
                                                        
                                                                Number of earth cores
                                                            
                                                            
                                                                1 
                                                            
                                                        Electrical characteristics
Electrical characteristics
                                                                Conductor AC resistance at 50 Hz
                                                            
                                                            
                                                                6.7 Ohm/km
                                                            
                                                        
                                                                Inductive reactance at 50Hz - flat touching
                                                            
                                                            
                                                                - Ohm/km
                                                            
                                                        
                                                                Inductive reactance at 50Hz - trefoil
                                                            
                                                            
                                                                - Ohm/km
                                                            
                                                        
                                                                Insulation resistance at 20°C
                                                            
                                                            
                                                                780 MOhm.km
                                                            
                                                        
                                                                Max. DC resistance of the conductor at 20°C
                                                            
                                                            
                                                                4.95 Ohm/km
                                                            
                                                        
                                                                Rated Voltage Uo/U (Um)
                                                            
                                                            
                                                                0,6/1 kV 
                                                            
                                                        Mechanical characteristics
Mechanical characteristics
                                                                Cable flexibility
                                                            
                                                            
                                                                Flexible for fixed application 
                                                            
                                                        
                                                                Mechanical resistance to impacts
                                                            
                                                            
                                                                Very good 
                                                            
                                                        Usage characteristics
Usage characteristics
                                                                Fire safety
                                                            
                                                            
                                                                - 
                                                            
                                                        
                                                                U.V resistance
                                                            
                                                            
                                                                Yes 
                                                            
                                                        
                                                                Maximum operating temperature
                                                            
                                                            
                                                                90 °C
                                                            
                                                        
                                                                Minimum operating temperature
                                                            
                                                            
                                                                -25 °C
                                                            
                                                        Resources
Resources
Documentation
                                                    Red List Free 2025
                                                    jpg — 1.1 MB
                                                
                                                
                                            Current carrying capacity tables - Envirolex multicore single phase
Flexible Copper Conductor Circular stranded Insulation X-HF-90 Max. Conductor Temperature 90⁰C| Conductor cross-section | 
                                                		 | 
                                                	
                                                		 | 
                                                	
                                                		 | 
                                                	
                                                		 | 
                                                	
                                                		 | 
                                                	
                                                		 | 
                                                	
                                                		 | 
                                                
|---|---|---|---|---|---|---|---|
| mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu | 
| 4.0 | 47 | 44 | 39 | 48 | 46 | 23 | 11.8 | 
| Air spaced from surface, unenclosed | 
| Air touching, unenclosed | 
| Air enclosed | 
| Buried direct | 
| Buried in single-way duct | 
| Cable surrounded by thermal insulation, unenclosed | 
| Voltage Drop Three Phase (mV/A.m) | 
Current carrying capacity table - Envirolex-Multicore (Three Phase)
Flexible Copper Conductor Circular stranded Insulation X-HF-90 Max. Conductor Temperature 90⁰C| Conductor cross-section | 
                                                		 | 
                                                	
                                                		 | 
                                                	
                                                		 | 
                                                	
                                                		 | 
                                                	
                                                		 | 
                                                	
                                                		 | 
                                                
|---|---|---|---|---|---|---|
| mm² | Cu | Cu | Cu | Cu | Cu | Cu | 
| 4.0 | 40 | 37 | 20 | 39 | 40 | 39 | 
| Air spaced from surface, unenclosed | 
| Air touching, unenclosed | 
| Cable surrounded by thermal insulation, unenclosed | 
| Air enclosed | 
| Buried direct | 
| Buried in single-way duct | 
Selling & delivery Information
Nexans Fire Safety Offer ENVIROLEX® Low Fire Hazard Cables PVC-free Red List Free and Declare Labelled Green Star Flexible conductor
Our websites
Select your country to find our products and solutions
- 
                        Africa
                        
                        
                        
- Africa
 - Ghana
 - Ivory Coast
 - Morocco
 - North West Africa
 
 - Americas
 - Asia
 - Europe
 - Oceania